|
|
SARS-CoV-2(2019-nCOV) IgM/IgG Antibody Coronavirus Rapid
Test Cassette
Catalog # |
Pack size |
Price($) |
COV00212 |
25tests |
150.00 |
The 2019-nCoV IgG/IgM Rapid Test Cassette (Whole
Blood/Serum/Plasma) is a qualitative membrane-based
immunoassay for the detection of IgG and IgM antibodies to
2019-nCoV in whole blood, serum or plasma specimen. This
test consists of two components, an IgG component and an IgM
component. In the IgG component, anti-human IgG is coated in
IgG test line region. During testing, the specimen reacts
with 2019-nCoV antigen-coated particles in the test
cassette. The mixture then migrates upward on the membrane
chromatographically by capillary action and reacts with the
anti-human IgG in IgG test line region, if the specimen
contains IgG antibodies to 2019-nCoV. A colored line will
appear in IgG test line region as a result of this.
Similarly, anti-human IgM is coated in IgM test line region
and if specimen contains IgM antibodies to 2019-nCoV, the
conjugate-specimen complex reacts with anti-human IgM. A
colored line appears in IgM test line region as a result.
Therefore, if the specimen contains 2019-nCoV IgG
antibodies, a colored line will appear in IgG test line
region. If the specimen contains 2019-nCoV IgM antibodies, a
colored line will appear in IgM test line region. If the
specimen does not contain 2019-nCoV antibodies, no colored
line will appear in either of the test line regions,
indicating a negative result. To serve as a procedural
control, a colored line will always appear in the control
line region, indicating that the proper volume of specimen
has been added and membrane wicking has occurred.
Storage condition:
Store
as packaged in the sealed pouch at room temperature or
refrigerated (2-30°C). The test is stable through the
expiration date printed on the sealed pouch. The test must
remain in the sealed pouch until use. DO NOT FREEZE. Do not
use beyond the expiration date.
Material:
Materials provided:
l
Test cassettes
l
Droppers
l
Buffer
l
Package insert
Materials required but not provided:
l
Specimen collection containers
l
Lancets (for fingerstick whole blood only)
l
Capillary tubes
l
Centrifuge (for plasma only)
l
Timer
l
Pipette
Test procedure:
Allow the test, specimen, buffer and/or controls to reach
room temperature (15-30°C) prior to testing.
1. Remove the test cassette from the foil pouch and use it
within one hour. Best results will be obtained if the test
is performed immediately after opening the foil pouch.
2. Place the cassette on a clean and level surface.
For Serum or Plasma specimen:
• To use a dropper: Hold the dropper vertically, draw the
specimen to the fill line (approximately 20uL), and transfer
the specimen to the specimen well (S), then add 2 drops of
buffer (approximately 80 uL), and start the timer.
• To use a pipette: To transfer 20 uL of specimen to the
specimen well(S), then add 2 drops of buffer (approximately
80 uL), and start the timer
For Venipuncture Whole Blood specimen:
• To use a dropper: Hold the dropper vertically, draw the
specimen about 1 cm above the fill line and transfer 1 full
drop (approx. 20μL) of specimen to the sample well(S). Then
add 2 drops of buffer (approximately 80 uL) and start the
timer.
• To use a pipette: To transfer 20 uL of whole blood to the
specimen well(S), then add 2 drops of buffer (approximately
80 uL), and start the timer
For Fingerstick Whole Blood specimen:
• To use a dropper: Hold the dropper vertically, draw the
specimen about 1 cm above the fill line and transfer 1 full
drop (approx. 20μL) of specimen to the sample well(S). Then
add 2 drops of buffer (approximately 80 uL) and start the
timer.
• To use a capillary tube: Fill the capillary tube and
transfer approximately 20uL of fingerstick whole blood
specimen to the specimen well (S) of test cassette, then add
2 drops of buffer (approximately 80 uL) and start the timer.
See illustration below.
3. Wait for the colored line(s) to appear. Read results at
10 minutes. Do not interpret the result after 20 minutes.
Note: It is suggested not to use the buffer, beyond 6 months
after opening the vial.
2019-nCoV(Sars-COV-2) IgM/IgG Antibody Coronavirus Rapid
Test Cassette
Handbook of COVID-19 Prevention and Treatment
If you want to get bulk order price,please contact us.E-mail:master@shinegene.org.cn or shinegene@vip.163.com
Related Link
Sars-CoV-2 Spike RBD
SARS-CoV-2 Primer and Probe
Oligo
Synthesis
Taqman probe
Peptide Synthesis
Chromas
Make Antibody
Lab Consumables
Gene Synthesis
dNTP
|
|